Energy-efficient induction motors designing with application of a modified criterion of reduced costs

The paper introduces a modified criterion of reduced costs that employs coefficients of operation significance and priority of ohmic loss accounting to allow matching maximum efficiency with minimum reduced costs. Impact of the inflation factor on the criterion of reduced costs is analyzed.

Bibliographic Details
Main Author: V.S. Petrushin
Format: Article
Language:English
Published: National Technical University "Kharkiv Polytechnic Institute" 2014-03-01
Series:Електротехніка і електромеханіка
Subjects:
Online Access:http://eie.khpi.edu.ua/article/view/22449/20070