Comparison between Modified MPC and DTC Control Method for Permanent Magnet Synchronous Motor

Direct torque control (DTC) and model predictive control (MPC) are widely used in the control of permanent magnet synchronous motor (PMSM). However, DTC for PMSM can cause large torque ripples and flux ripples, high harmonic distortion of the stator current, and high acoustic noises. Compared to DTC...

Full description

Bibliographic Details
Main Authors: Li Huanyu, Li Miao, Zhengs Chenhong, Chen Bingqian
Format: Article
Language:English
Published: EDP Sciences 2019-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/41/e3sconf_ceege18_02004.pdf