The Influence of Flooding Phenomenon to Pressure Drop on Hotleg Simulator with L/D=25

Cooling system in nuclear reactor is much influenced by counter-current flow. When a leakage is occured, coolant in primary circuit of hotleg and hot steam from reactor will flows in counter-current condition. An experimental investigation has been performed to examine the effect of flooding phenome...

Full description

Bibliographic Details
Main Authors: Marcellinus Sindhu, Apip Badarudin, Indarto, Deendarlianto, Sinung Tirtha, Venti Yoanita, Suprianta Setiawan Putra
Format: Article
Language:English
Published: University of Muhammadiyah Malang 2017-11-01
Series:JEMMME (Journal of Energy, Mechanical, Material, and Manufacturing Engineering)
Subjects: