Reliably-oriented analysis of a single stage cooler thermoelement construction

The object of research is a model of the relationship between the reliability indicators of a single stage thermoelectric cooler and the geometry of the thermoelement, i.e., the ratio of its length to the cross-sectional area. Existing studies are limited to analyzing the influence of the geometry o...

Full description

Bibliographic Details
Main Authors: Vladimir Zaykov, Vladimir Mescheryakov, Yurii Zhuravlov
Format: Article
Language:English
Published: PC Technology Center 2017-03-01
Series:Tehnologìčnij Audit ta Rezervi Virobnictva
Subjects:
Online Access:http://journals.uran.ua/tarp/article/view/100058