Mechanical instability and titanium particles induce similar transcriptomic changes in a rat model for periprosthetic osteolysis and aseptic loosening

Wear debris particles released from prosthetic bearing surfaces and mechanical instability of implants are two main causes of periprosthetic osteolysis. While particle-induced loosening has been studied extensively, mechanisms through which mechanical factors lead to implant loosening have been less...

Full description

Bibliographic Details
Main Authors: Mehdi Amirhosseini, Göran Andersson, Per Aspenberg, Anna Fahlgren
Format: Article
Language:English
Published: Elsevier 2017-12-01
Series:Bone Reports
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2352187217300219
id doaj-211673333fdc4537bbd7753f60e62f20
record_format Article
spelling doaj-211673333fdc4537bbd7753f60e62f202020-11-24T23:37:29ZengElsevierBone Reports2352-18722017-12-017C172510.1016/j.bonr.2017.07.003Mechanical instability and titanium particles induce similar transcriptomic changes in a rat model for periprosthetic osteolysis and aseptic looseningMehdi Amirhosseini0Göran Andersson1Per Aspenberg2Anna Fahlgren3Division of Cell Biology, Department of Clinical and Experimental Medicine, Faculty of Medicine and Health Sciences, Linköping University, Linköping, SwedenDivision of Pathology, Department of Laboratory Medicine, Karolinska Institutet, Karolinska University Hospital, Huddinge, SwedenOrthopedics, Department of Clinical and Experimental Medicine, Faculty of Medicine and Health Sciences, Linköping University, Linköping, SwedenDivision of Cell Biology, Department of Clinical and Experimental Medicine, Faculty of Medicine and Health Sciences, Linköping University, Linköping, SwedenWear debris particles released from prosthetic bearing surfaces and mechanical instability of implants are two main causes of periprosthetic osteolysis. While particle-induced loosening has been studied extensively, mechanisms through which mechanical factors lead to implant loosening have been less investigated. This study compares the transcriptional profiles associated with osteolysis in a rat model for aseptic loosening, induced by either mechanical instability or titanium particles. Rats were exposed to mechanical instability or titanium particles. After 15 min, 3, 48 or 120 h from start of the stimulation, gene expression changes in periprosthetic bone tissue was determined by microarray analysis. Microarray data were analyzed by PANTHER Gene List Analysis tool and Ingenuity Pathway Analysis (IPA). Both types of osteolytic stimulation led to gene regulation in comparison to unstimulated controls after 3, 48 or 120 h. However, when mechanical instability was compared to titanium particles, no gene showed a statistically significant difference (fold change ≥ ±1.5 and adjusted p-value ≤ 0.05) at any time point. There was a remarkable similarity in numbers and functional classification of regulated genes. Pathway analysis showed several inflammatory pathways activated by both stimuli, including Acute Phase Response signaling, IL-6 signaling and Oncostatin M signaling. Quantitative PCR confirmed the changes in expression of key genes involved in osteolysis observed by global transcriptomics. Inflammatory mediators including interleukin (IL)-6, IL-1β, chemokine (C-C motif) ligand (CCL)2, prostaglandin-endoperoxide synthase (Ptgs)2 and leukemia inhibitory factor (LIF) showed strong upregulation, as assessed by both microarray and qPCR. By investigating genome-wide expression changes we show that, despite the different nature of mechanical implant instability and titanium particles, osteolysis seems to be induced through similar biological and signaling pathways in this rat model for aseptic loosening. Pathways associated to the innate inflammatory response appear to be a major driver for osteolysis. Our findings implicate early restriction of inflammation to be critical to prevent or mitigate osteolysis and aseptic loosening of orthopedic implants.http://www.sciencedirect.com/science/article/pii/S2352187217300219Aseptic looseningImplantInstabilityWear debrisMicroarray
collection DOAJ
language English
format Article
sources DOAJ
author Mehdi Amirhosseini
Göran Andersson
Per Aspenberg
Anna Fahlgren
spellingShingle Mehdi Amirhosseini
Göran Andersson
Per Aspenberg
Anna Fahlgren
Mechanical instability and titanium particles induce similar transcriptomic changes in a rat model for periprosthetic osteolysis and aseptic loosening
Bone Reports
Aseptic loosening
Implant
Instability
Wear debris
Microarray
author_facet Mehdi Amirhosseini
Göran Andersson
Per Aspenberg
Anna Fahlgren
author_sort Mehdi Amirhosseini
title Mechanical instability and titanium particles induce similar transcriptomic changes in a rat model for periprosthetic osteolysis and aseptic loosening
title_short Mechanical instability and titanium particles induce similar transcriptomic changes in a rat model for periprosthetic osteolysis and aseptic loosening
title_full Mechanical instability and titanium particles induce similar transcriptomic changes in a rat model for periprosthetic osteolysis and aseptic loosening
title_fullStr Mechanical instability and titanium particles induce similar transcriptomic changes in a rat model for periprosthetic osteolysis and aseptic loosening
title_full_unstemmed Mechanical instability and titanium particles induce similar transcriptomic changes in a rat model for periprosthetic osteolysis and aseptic loosening
title_sort mechanical instability and titanium particles induce similar transcriptomic changes in a rat model for periprosthetic osteolysis and aseptic loosening
publisher Elsevier
series Bone Reports
issn 2352-1872
publishDate 2017-12-01
description Wear debris particles released from prosthetic bearing surfaces and mechanical instability of implants are two main causes of periprosthetic osteolysis. While particle-induced loosening has been studied extensively, mechanisms through which mechanical factors lead to implant loosening have been less investigated. This study compares the transcriptional profiles associated with osteolysis in a rat model for aseptic loosening, induced by either mechanical instability or titanium particles. Rats were exposed to mechanical instability or titanium particles. After 15 min, 3, 48 or 120 h from start of the stimulation, gene expression changes in periprosthetic bone tissue was determined by microarray analysis. Microarray data were analyzed by PANTHER Gene List Analysis tool and Ingenuity Pathway Analysis (IPA). Both types of osteolytic stimulation led to gene regulation in comparison to unstimulated controls after 3, 48 or 120 h. However, when mechanical instability was compared to titanium particles, no gene showed a statistically significant difference (fold change ≥ ±1.5 and adjusted p-value ≤ 0.05) at any time point. There was a remarkable similarity in numbers and functional classification of regulated genes. Pathway analysis showed several inflammatory pathways activated by both stimuli, including Acute Phase Response signaling, IL-6 signaling and Oncostatin M signaling. Quantitative PCR confirmed the changes in expression of key genes involved in osteolysis observed by global transcriptomics. Inflammatory mediators including interleukin (IL)-6, IL-1β, chemokine (C-C motif) ligand (CCL)2, prostaglandin-endoperoxide synthase (Ptgs)2 and leukemia inhibitory factor (LIF) showed strong upregulation, as assessed by both microarray and qPCR. By investigating genome-wide expression changes we show that, despite the different nature of mechanical implant instability and titanium particles, osteolysis seems to be induced through similar biological and signaling pathways in this rat model for aseptic loosening. Pathways associated to the innate inflammatory response appear to be a major driver for osteolysis. Our findings implicate early restriction of inflammation to be critical to prevent or mitigate osteolysis and aseptic loosening of orthopedic implants.
topic Aseptic loosening
Implant
Instability
Wear debris
Microarray
url http://www.sciencedirect.com/science/article/pii/S2352187217300219
work_keys_str_mv AT mehdiamirhosseini mechanicalinstabilityandtitaniumparticlesinducesimilartranscriptomicchangesinaratmodelforperiprostheticosteolysisandasepticloosening
AT goranandersson mechanicalinstabilityandtitaniumparticlesinducesimilartranscriptomicchangesinaratmodelforperiprostheticosteolysisandasepticloosening
AT peraspenberg mechanicalinstabilityandtitaniumparticlesinducesimilartranscriptomicchangesinaratmodelforperiprostheticosteolysisandasepticloosening
AT annafahlgren mechanicalinstabilityandtitaniumparticlesinducesimilartranscriptomicchangesinaratmodelforperiprostheticosteolysisandasepticloosening
_version_ 1725519700231716864