Development And Validation Of Stability Indicating RP-HPLC Method For Determination Of Ceritinib

A new, simple, specific, accurate and precise RP-HPLC method was developed for determination of Ceritinib. In the present study, stress testing of Ceritinib was carried out according to ICH guidelines Q1A (R2). Ceritinib was subjected to stress conditions of hydrolysis, oxidation, photolysis and neu...