Design, Experiment, and Commissioning of the Passive Residual Heat Removal System of China’s Generation III Nuclear Power HPR1000

In response to a station blackout accident similar to the Fukushima nuclear accident, China’s Generation III nuclear power HPR1000 designed and developed a passive residual heat removal system connected to the secondary side of the steam generator. Based on the two-phase natural circulation principl...

Full description

Bibliographic Details
Main Authors: Feng Li, Yazhe Lu, Xiao Chu, Qiang Zheng, Guanghao Wu
Format: Article
Language:English
Published: Hindawi Limited 2021-01-01
Series:Science and Technology of Nuclear Installations