Preliminary analysis of dry-steam geothermal power plant by employing exergy assessment: Case study in Kamojang geothermal power plant, Indonesia

The objectives of this study are to perform the exergy analysis and ambient temperature optimization of the Kamojang geothermal power plant by employing Engineering Equation Solver (EES). The geothermal capacity is 55 MW and the field is vapor-dominated reservoir with temperature 245 °C. In the init...

Full description

Bibliographic Details
Main Authors: Bayu Rudiyanto, IbnuAtho Illah, Nugroho Agung Pambudi, Chin-Chi Cheng, Reza Adiprana, Muhammad Imran, Lip Huat Saw, Renanto Handogo
Format: Article
Language:English
Published: Elsevier 2017-09-01
Series:Case Studies in Thermal Engineering
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2214157X17301272