Design and Implementation of a Clamper-Based and Motor-Driven Capsule Robot Powered by Wireless Power Transmission
This paper proposes a clamper-based and motor-driven capsule robot (CMCR) for exploring the intestinal tract. The CMCR, measuring Φ14 mm×46.8 mm, is composed of a front facing camera, a clamper-based locomotion mechanism (LM), a telemetry circuit, and a solid-cylinder three-dim...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
IEEE
2019-01-01
|
Series: | IEEE Access |
Subjects: | |
Online Access: | https://ieeexplore.ieee.org/document/8839037/ |
id |
doaj-395eef8e7559499d99d95435a6fcc80e |
---|---|
record_format |
Article |
spelling |
doaj-395eef8e7559499d99d95435a6fcc80e2021-03-29T23:13:15ZengIEEEIEEE Access2169-35362019-01-01713815113816110.1109/ACCESS.2019.29415628839037Design and Implementation of a Clamper-Based and Motor-Driven Capsule Robot Powered by Wireless Power TransmissionJinyang Gao0https://orcid.org/0000-0001-8247-1196Guozheng Yan1Science and Technology on Electronic Test and Measurement Laboratory, North University of China, Taiyuan, ChinaDepartment of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai, ChinaThis paper proposes a clamper-based and motor-driven capsule robot (CMCR) for exploring the intestinal tract. The CMCR, measuring Φ14 mm×46.8 mm, is composed of a front facing camera, a clamper-based locomotion mechanism (LM), a telemetry circuit, and a solid-cylinder three-dimensional (3-D) receiving coil for wireless power induction. The LM consists of a translational mechanism (TM), a free clamper that can be moved linearly by the TM, and a fixed clamper. The two clampers both employ arc-shaped legs for expanding with diameters that range from 14 mm to 31 mm; and they can cooperate with the TM to simulate active locomotion in two modes. One mode contains four gaits and is used in an almost horizontal intestine, while the other mode contains six gaits and is used when the CMCR moves in a sloped intestine or against intestinal peristalsis. The solid-cylinder 3-D receiving coil is designed with an aim of maximizing its output power within a given available space, which is achieved by optimizing its design parameters with a calculation-based design method. Finally, the CMCR performance is tested: it works properly when powered by the solid-cylinder 3-D receiving coil, and has a satisfactory speed of 6.32 cm/min in a horizontal ex-vivo intestine and 2.69 cm/min in a vertical one. These test results indicate that the CMCR is promising for a minimally invasive intestinal exploration.https://ieeexplore.ieee.org/document/8839037/Capsule robotlocomotion mechanismsolid-cylinder 3-D receiving coilintestinal exploration |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Jinyang Gao Guozheng Yan |
spellingShingle |
Jinyang Gao Guozheng Yan Design and Implementation of a Clamper-Based and Motor-Driven Capsule Robot Powered by Wireless Power Transmission IEEE Access Capsule robot locomotion mechanism solid-cylinder 3-D receiving coil intestinal exploration |
author_facet |
Jinyang Gao Guozheng Yan |
author_sort |
Jinyang Gao |
title |
Design and Implementation of a Clamper-Based and Motor-Driven Capsule Robot Powered by Wireless Power Transmission |
title_short |
Design and Implementation of a Clamper-Based and Motor-Driven Capsule Robot Powered by Wireless Power Transmission |
title_full |
Design and Implementation of a Clamper-Based and Motor-Driven Capsule Robot Powered by Wireless Power Transmission |
title_fullStr |
Design and Implementation of a Clamper-Based and Motor-Driven Capsule Robot Powered by Wireless Power Transmission |
title_full_unstemmed |
Design and Implementation of a Clamper-Based and Motor-Driven Capsule Robot Powered by Wireless Power Transmission |
title_sort |
design and implementation of a clamper-based and motor-driven capsule robot powered by wireless power transmission |
publisher |
IEEE |
series |
IEEE Access |
issn |
2169-3536 |
publishDate |
2019-01-01 |
description |
This paper proposes a clamper-based and motor-driven capsule robot (CMCR) for exploring the intestinal tract. The CMCR, measuring Φ14 mm×46.8 mm, is composed of a front facing camera, a clamper-based locomotion mechanism (LM), a telemetry circuit, and a solid-cylinder three-dimensional (3-D) receiving coil for wireless power induction. The LM consists of a translational mechanism (TM), a free clamper that can be moved linearly by the TM, and a fixed clamper. The two clampers both employ arc-shaped legs for expanding with diameters that range from 14 mm to 31 mm; and they can cooperate with the TM to simulate active locomotion in two modes. One mode contains four gaits and is used in an almost horizontal intestine, while the other mode contains six gaits and is used when the CMCR moves in a sloped intestine or against intestinal peristalsis. The solid-cylinder 3-D receiving coil is designed with an aim of maximizing its output power within a given available space, which is achieved by optimizing its design parameters with a calculation-based design method. Finally, the CMCR performance is tested: it works properly when powered by the solid-cylinder 3-D receiving coil, and has a satisfactory speed of 6.32 cm/min in a horizontal ex-vivo intestine and 2.69 cm/min in a vertical one. These test results indicate that the CMCR is promising for a minimally invasive intestinal exploration. |
topic |
Capsule robot locomotion mechanism solid-cylinder 3-D receiving coil intestinal exploration |
url |
https://ieeexplore.ieee.org/document/8839037/ |
work_keys_str_mv |
AT jinyanggao designandimplementationofaclamperbasedandmotordrivencapsulerobotpoweredbywirelesspowertransmission AT guozhengyan designandimplementationofaclamperbasedandmotordrivencapsulerobotpoweredbywirelesspowertransmission |
_version_ |
1724189852886368256 |