USE OF STRONG ACID RESIN PUROLITE C100E FOR REMOVING PERMANENT HARDNESS OF WATER – FACTORS AFFECTING CATIONIC EXCHANGE CAPACITY

This paper experimentally investigates the performance and capacity of Purolite C100E commercial resin recommended for water softening applications in the food industry. The practical ion exchange capacity and the softening process efficiency are studied in batch mode as a function of the sorption s...

Full description

Bibliographic Details
Main Authors: BOGDAN BANDRABUR, RAMONA-ELENA TATARU-FĂRMUŞ, LILIANA LAZĂR, LAURA BULGARIU, GHEORGHE GUTT
Format: Article
Language:English
Published: Alma Mater Publishing House "Vasile Alecsandri" University of Bacau 2013-12-01
Series:Scientific Study & Research: Chemistry & Chemical Engineering, Biotechnology, Food Industry
Subjects:
Online Access:http://pubs.ub.ro/?pg=revues&rev=cscc6&num=201203&vol=3&aid=3866
id doaj-3b7667481e2945b483a280602822be92
record_format Article
spelling doaj-3b7667481e2945b483a280602822be922020-11-24T22:50:21ZengAlma Mater Publishing House "Vasile Alecsandri" University of BacauScientific Study & Research: Chemistry & Chemical Engineering, Biotechnology, Food Industry1582-540X2013-12-01133295304USE OF STRONG ACID RESIN PUROLITE C100E FOR REMOVING PERMANENT HARDNESS OF WATER – FACTORS AFFECTING CATIONIC EXCHANGE CAPACITYBOGDAN BANDRABUR 0RAMONA-ELENA TATARU-FĂRMUŞ 1LILIANA LAZĂR 2LAURA BULGARIU 3 GHEORGHE GUTT 4.”Stefan cel Mare” University of Suceava, Faculty of Food Engineering, 13 University Street, 720229 - Suceava, Romania”Gheorghe Asachi” Technical University of Iasi, Faculty of Chemical Engineering and Environmental Protection, 73 Prof. dr. doc. D. Mangeron Street, 700050 - Iasi, Romania”Gheorghe Asachi” Technical University of Iasi, Faculty of Chemical Engineering and Environmental Protection, 73 Prof. dr. doc. D. Mangeron Street, 700050 - Iasi, Romania”Gheorghe Asachi” Technical University of Iasi, Faculty of Chemical Engineering and Environmental Protection, 73 Prof. dr. doc. D. Mangeron Street, 700050 - Iasi, Romania.”Stefan cel Mare” University of Suceava, Faculty of Food Engineering, 13 University Street, 720229 - Suceava, RomaniaThis paper experimentally investigates the performance and capacity of Purolite C100E commercial resin recommended for water softening applications in the food industry. The practical ion exchange capacity and the softening process efficiency are studied in batch mode as a function of the sorption specific process factors. Optimum operation conditions were determined as initial pH 7.1, resin dose 8 g dry resin•L-1, temperature 25 oC, contact time of 360 min, and in those conditions the retention capacity for the Ca2+ ions is 17.18 mg•g-1 that corresponds to a removal efficiency equal to 85.7%.http://pubs.ub.ro/?pg=revues&rev=cscc6&num=201203&vol=3&aid=3866calcium removalfood grade resinion exchangewater softening
collection DOAJ
language English
format Article
sources DOAJ
author BOGDAN BANDRABUR
RAMONA-ELENA TATARU-FĂRMUŞ
LILIANA LAZĂR
LAURA BULGARIU
GHEORGHE GUTT
spellingShingle BOGDAN BANDRABUR
RAMONA-ELENA TATARU-FĂRMUŞ
LILIANA LAZĂR
LAURA BULGARIU
GHEORGHE GUTT
USE OF STRONG ACID RESIN PUROLITE C100E FOR REMOVING PERMANENT HARDNESS OF WATER – FACTORS AFFECTING CATIONIC EXCHANGE CAPACITY
Scientific Study & Research: Chemistry & Chemical Engineering, Biotechnology, Food Industry
calcium removal
food grade resin
ion exchange
water softening
author_facet BOGDAN BANDRABUR
RAMONA-ELENA TATARU-FĂRMUŞ
LILIANA LAZĂR
LAURA BULGARIU
GHEORGHE GUTT
author_sort BOGDAN BANDRABUR
title USE OF STRONG ACID RESIN PUROLITE C100E FOR REMOVING PERMANENT HARDNESS OF WATER – FACTORS AFFECTING CATIONIC EXCHANGE CAPACITY
title_short USE OF STRONG ACID RESIN PUROLITE C100E FOR REMOVING PERMANENT HARDNESS OF WATER – FACTORS AFFECTING CATIONIC EXCHANGE CAPACITY
title_full USE OF STRONG ACID RESIN PUROLITE C100E FOR REMOVING PERMANENT HARDNESS OF WATER – FACTORS AFFECTING CATIONIC EXCHANGE CAPACITY
title_fullStr USE OF STRONG ACID RESIN PUROLITE C100E FOR REMOVING PERMANENT HARDNESS OF WATER – FACTORS AFFECTING CATIONIC EXCHANGE CAPACITY
title_full_unstemmed USE OF STRONG ACID RESIN PUROLITE C100E FOR REMOVING PERMANENT HARDNESS OF WATER – FACTORS AFFECTING CATIONIC EXCHANGE CAPACITY
title_sort use of strong acid resin purolite c100e for removing permanent hardness of water – factors affecting cationic exchange capacity
publisher Alma Mater Publishing House "Vasile Alecsandri" University of Bacau
series Scientific Study & Research: Chemistry & Chemical Engineering, Biotechnology, Food Industry
issn 1582-540X
publishDate 2013-12-01
description This paper experimentally investigates the performance and capacity of Purolite C100E commercial resin recommended for water softening applications in the food industry. The practical ion exchange capacity and the softening process efficiency are studied in batch mode as a function of the sorption specific process factors. Optimum operation conditions were determined as initial pH 7.1, resin dose 8 g dry resin•L-1, temperature 25 oC, contact time of 360 min, and in those conditions the retention capacity for the Ca2+ ions is 17.18 mg•g-1 that corresponds to a removal efficiency equal to 85.7%.
topic calcium removal
food grade resin
ion exchange
water softening
url http://pubs.ub.ro/?pg=revues&rev=cscc6&num=201203&vol=3&aid=3866
work_keys_str_mv AT bogdanbandrabur useofstrongacidresinpurolitec100eforremovingpermanenthardnessofwaterfactorsaffectingcationicexchangecapacity
AT ramonaelenatatarufarmus useofstrongacidresinpurolitec100eforremovingpermanenthardnessofwaterfactorsaffectingcationicexchangecapacity
AT lilianalazar useofstrongacidresinpurolitec100eforremovingpermanenthardnessofwaterfactorsaffectingcationicexchangecapacity
AT laurabulgariu useofstrongacidresinpurolitec100eforremovingpermanenthardnessofwaterfactorsaffectingcationicexchangecapacity
AT gheorghegutt useofstrongacidresinpurolitec100eforremovingpermanenthardnessofwaterfactorsaffectingcationicexchangecapacity
_version_ 1725672831244566528