Elimination of interferences from surface active substances in voltammetric determination of trace amounts of titanium in environmental water samples

A cathodic stripping voltammetric method for determination of Ti(IV) in water samples containing high concentrations of surfactants is described. The linear calibration plot for Ti(IV) was achieved in the simultaneous presence of 5 mg L-1 anionic, 1 mg L-1 cationic and 2 mg L-1 nonionic surfactants...