Calculation of the Median Lethal Dose and Low Lethal Dose Using the CombiStats Biometric Software

The median lethal dose (LD50) and low lethal dose (LD10) are calculated in acute toxicity studies, as well as during specific activity assessment of some medicines. The aim of the study was to develop a procedure for using CombiStats to calculate LD50 and LD10. The authors proposed a step-by-step al...

Full description

Bibliographic Details
Main Authors: P. V. Shadrin, T. A. Batuashvili, L. V. Simutenko, N. P. Neugodova
Format: Article
Language:Russian
Published: OOO “Vashe Tsifrovoe Izdatelstvo” 2021-07-01
Series:Ведомости Научного центра экспертизы средств медицинского применения
Subjects:
Online Access:https://www.vedomostincesmp.ru/jour/article/view/344
id doaj-45ae5520b30d449bb6d15a3c39549b74
record_format Article
spelling doaj-45ae5520b30d449bb6d15a3c39549b742021-07-28T14:04:10ZrusOOO “Vashe Tsifrovoe Izdatelstvo”Ведомости Научного центра экспертизы средств медицинского применения1991-29192619-11722021-07-0111213514210.30895/1991-2919-2021-11-2-135-142265Calculation of the Median Lethal Dose and Low Lethal Dose Using the CombiStats Biometric SoftwareP. V. Shadrin0T. A. Batuashvili1L. V. Simutenko2N. P. Neugodova3Scientific Centre for Expert Evaluation of Medicinal ProductsScientific Centre for Expert Evaluation of Medicinal ProductsScientific Centre for Expert Evaluation of Medicinal ProductsScientific Centre for Expert Evaluation of Medicinal ProductsThe median lethal dose (LD50) and low lethal dose (LD10) are calculated in acute toxicity studies, as well as during specific activity assessment of some medicines. The aim of the study was to develop a procedure for using CombiStats to calculate LD50 and LD10. The authors proposed a step-by-step algorithm for processing bioassay results using the CombiStats biometric software (median effective dose determination model, probit analysis) with conversion of doses to simple fractions (fractions of the maximum dose) to calculate LD50 and LD10. They compared LD50 and LD10 calculation results obtained using CombiStats with those obtained using electronic spreadsheets according to the Bliss–Miller–Tainter–Prozorovsky method described in the State Pharmacopoeia of the Russian Federation (General Monograph 1.1.0014.15). It has been demonstrated that the use of CombiStats sometimes has advantages over the use of the pharmacoepoeial method.https://www.vedomostincesmp.ru/jour/article/view/344median lethal doseld<sub>50</sub>median effective doseed<sub>50</sub>low lethal doseld<sub>10</sub>combistatsbiometric softwaredose conversionmedicinal productssnake venom
collection DOAJ
language Russian
format Article
sources DOAJ
author P. V. Shadrin
T. A. Batuashvili
L. V. Simutenko
N. P. Neugodova
spellingShingle P. V. Shadrin
T. A. Batuashvili
L. V. Simutenko
N. P. Neugodova
Calculation of the Median Lethal Dose and Low Lethal Dose Using the CombiStats Biometric Software
Ведомости Научного центра экспертизы средств медицинского применения
median lethal dose
ld<sub>50</sub>
median effective dose
ed<sub>50</sub>
low lethal dose
ld<sub>10</sub>
combistats
biometric software
dose conversion
medicinal products
snake venom
author_facet P. V. Shadrin
T. A. Batuashvili
L. V. Simutenko
N. P. Neugodova
author_sort P. V. Shadrin
title Calculation of the Median Lethal Dose and Low Lethal Dose Using the CombiStats Biometric Software
title_short Calculation of the Median Lethal Dose and Low Lethal Dose Using the CombiStats Biometric Software
title_full Calculation of the Median Lethal Dose and Low Lethal Dose Using the CombiStats Biometric Software
title_fullStr Calculation of the Median Lethal Dose and Low Lethal Dose Using the CombiStats Biometric Software
title_full_unstemmed Calculation of the Median Lethal Dose and Low Lethal Dose Using the CombiStats Biometric Software
title_sort calculation of the median lethal dose and low lethal dose using the combistats biometric software
publisher OOO “Vashe Tsifrovoe Izdatelstvo”
series Ведомости Научного центра экспертизы средств медицинского применения
issn 1991-2919
2619-1172
publishDate 2021-07-01
description The median lethal dose (LD50) and low lethal dose (LD10) are calculated in acute toxicity studies, as well as during specific activity assessment of some medicines. The aim of the study was to develop a procedure for using CombiStats to calculate LD50 and LD10. The authors proposed a step-by-step algorithm for processing bioassay results using the CombiStats biometric software (median effective dose determination model, probit analysis) with conversion of doses to simple fractions (fractions of the maximum dose) to calculate LD50 and LD10. They compared LD50 and LD10 calculation results obtained using CombiStats with those obtained using electronic spreadsheets according to the Bliss–Miller–Tainter–Prozorovsky method described in the State Pharmacopoeia of the Russian Federation (General Monograph 1.1.0014.15). It has been demonstrated that the use of CombiStats sometimes has advantages over the use of the pharmacoepoeial method.
topic median lethal dose
ld<sub>50</sub>
median effective dose
ed<sub>50</sub>
low lethal dose
ld<sub>10</sub>
combistats
biometric software
dose conversion
medicinal products
snake venom
url https://www.vedomostincesmp.ru/jour/article/view/344
work_keys_str_mv AT pvshadrin calculationofthemedianlethaldoseandlowlethaldoseusingthecombistatsbiometricsoftware
AT tabatuashvili calculationofthemedianlethaldoseandlowlethaldoseusingthecombistatsbiometricsoftware
AT lvsimutenko calculationofthemedianlethaldoseandlowlethaldoseusingthecombistatsbiometricsoftware
AT npneugodova calculationofthemedianlethaldoseandlowlethaldoseusingthecombistatsbiometricsoftware
_version_ 1721268472876367872