Real-time isothermal nucleic acid amplification detection in resource-limited settings: a description of an open-source miniature fluorimeter

Background: The detection and quantification of nucleic acids traditionally relies on PCR, which requires the use of expensive thermocyclers with integrated fluorescence detection of amplicons. While isothermal nucleic acid amplification technologies eliminate the need for thermocycling, fluorescenc...

Full description

Bibliographic Details
Main Authors: Jackson Coole, BS, Alex Kortum, MSc, Yubo Tang, PhD, Imran Vohra, BS, Mary Natoli, PhD, Kathryn Kundrod, PhD, Rebecca Richards-Kortum, PhD
Format: Article
Language:English
Published: Elsevier 2021-03-01
Series:The Lancet Global Health
Online Access:http://www.sciencedirect.com/science/article/pii/S2214109X21001145
id doaj-5072a5125cbb464ba5aaa7d89e0ec380
record_format Article
spelling doaj-5072a5125cbb464ba5aaa7d89e0ec3802021-03-13T04:22:41ZengElsevierThe Lancet Global Health2214-109X2021-03-019S6Real-time isothermal nucleic acid amplification detection in resource-limited settings: a description of an open-source miniature fluorimeterJackson Coole, BS0Alex Kortum, MSc1Yubo Tang, PhD2Imran Vohra, BS3Mary Natoli, PhD4Kathryn Kundrod, PhD5Rebecca Richards-Kortum, PhD6Rice University, Department of Bioengineering, Houston TX, USARice University, Department of Bioengineering, Houston TX, USARice University, Department of Bioengineering, Houston TX, USARice University, Department of Bioengineering, Houston TX, USARice University, Department of Bioengineering, Houston TX, USARice University, Department of Bioengineering, Houston TX, USARice University, Department of Bioengineering, Houston TX, USA; Correspondence to: Dr Rebecca Richards-Kortum 6100 Main St, MS-142, Houston, TX 77005, USABackground: The detection and quantification of nucleic acids traditionally relies on PCR, which requires the use of expensive thermocyclers with integrated fluorescence detection of amplicons. While isothermal nucleic acid amplification technologies eliminate the need for thermocycling, fluorescence-based detection of products is still required for real-time, quantitative readout. Several commercially available isothermal heaters with integrated fluorescence detection exist, but the cost of these devices remains a significant barrier to the use of isothermal nucleic acid amplification in low-resource settings. A low-cost device for nucleic acid amplification detection could be used to contain the spread of the SARS-CoV-2 virus during the current pandemic as well as other disease targets in the future. Increasing COVID-19 testing capacity is particularly relevant when variations of the virus that appear to be more infectious are spreading rapidly and efforts to scale up delivery of COVID-19 vaccines are in the early stages. Here, we describe a modular, low-cost fluorimeter for use in resource-limited settings that lack access to and infrastructure for traditional testing platforms. Methods: We present a fluorimeter that is constructed from off-the-shelf components enclosed in a compact 3D printed housing that removes the need for specialised optical alignment. The fluorimeter is designed to be placed atop a commercially available heat block holding a PCR-tube and was optimised to detect fluorescein (FITC) dye. The modular design allows it to be easily adapted for use with other dyes commonly used as reporters in nucleic acid amplification reactions. Findings: Clinical applicability of the system was demonstrated using the system to measure amplification with two different isothermal amplification technologies with significantly different temperature, volume, and fluorescence requirements: recombinase polymerase amplification (RPA) and reverse transcription loop-mediated isothermal amplification (RT-LAMP). RPA detection was demonstrated with a positive control DNA provided in a commercial kit while RT-LAMP detection of clinically meaningful levels of SARS-CoV-2 RNA was demonstrated in a custom RT-LAMP assay. In a preliminary analysis of nasopharyngeal swab samples from 74 individuals, the custom RT-LAMP assay showed a positive agreement of 92·3% and a negative agreement of 91·4% with the SARS-CoV-2 RT-qPCR test developed by the US Centers for Disease Control and Prevention. Interpretation: This open-source system was designed to improve accessibility to nucleic acid testing with isothermal amplification methods. The system can be easily produced using only a low-end 3D printer. Moreover, the use of single-board computers obviates the need to produce printed circuit boards. At a time when global supply chains are at their most fragile, open-source diagnostic equipment has the potential to reduce pandemic-related health inequities. Funding: International AIDS vaccine Initiative IAVI and USAID: award AID-OAA-A16-00032.http://www.sciencedirect.com/science/article/pii/S2214109X21001145
collection DOAJ
language English
format Article
sources DOAJ
author Jackson Coole, BS
Alex Kortum, MSc
Yubo Tang, PhD
Imran Vohra, BS
Mary Natoli, PhD
Kathryn Kundrod, PhD
Rebecca Richards-Kortum, PhD
spellingShingle Jackson Coole, BS
Alex Kortum, MSc
Yubo Tang, PhD
Imran Vohra, BS
Mary Natoli, PhD
Kathryn Kundrod, PhD
Rebecca Richards-Kortum, PhD
Real-time isothermal nucleic acid amplification detection in resource-limited settings: a description of an open-source miniature fluorimeter
The Lancet Global Health
author_facet Jackson Coole, BS
Alex Kortum, MSc
Yubo Tang, PhD
Imran Vohra, BS
Mary Natoli, PhD
Kathryn Kundrod, PhD
Rebecca Richards-Kortum, PhD
author_sort Jackson Coole, BS
title Real-time isothermal nucleic acid amplification detection in resource-limited settings: a description of an open-source miniature fluorimeter
title_short Real-time isothermal nucleic acid amplification detection in resource-limited settings: a description of an open-source miniature fluorimeter
title_full Real-time isothermal nucleic acid amplification detection in resource-limited settings: a description of an open-source miniature fluorimeter
title_fullStr Real-time isothermal nucleic acid amplification detection in resource-limited settings: a description of an open-source miniature fluorimeter
title_full_unstemmed Real-time isothermal nucleic acid amplification detection in resource-limited settings: a description of an open-source miniature fluorimeter
title_sort real-time isothermal nucleic acid amplification detection in resource-limited settings: a description of an open-source miniature fluorimeter
publisher Elsevier
series The Lancet Global Health
issn 2214-109X
publishDate 2021-03-01
description Background: The detection and quantification of nucleic acids traditionally relies on PCR, which requires the use of expensive thermocyclers with integrated fluorescence detection of amplicons. While isothermal nucleic acid amplification technologies eliminate the need for thermocycling, fluorescence-based detection of products is still required for real-time, quantitative readout. Several commercially available isothermal heaters with integrated fluorescence detection exist, but the cost of these devices remains a significant barrier to the use of isothermal nucleic acid amplification in low-resource settings. A low-cost device for nucleic acid amplification detection could be used to contain the spread of the SARS-CoV-2 virus during the current pandemic as well as other disease targets in the future. Increasing COVID-19 testing capacity is particularly relevant when variations of the virus that appear to be more infectious are spreading rapidly and efforts to scale up delivery of COVID-19 vaccines are in the early stages. Here, we describe a modular, low-cost fluorimeter for use in resource-limited settings that lack access to and infrastructure for traditional testing platforms. Methods: We present a fluorimeter that is constructed from off-the-shelf components enclosed in a compact 3D printed housing that removes the need for specialised optical alignment. The fluorimeter is designed to be placed atop a commercially available heat block holding a PCR-tube and was optimised to detect fluorescein (FITC) dye. The modular design allows it to be easily adapted for use with other dyes commonly used as reporters in nucleic acid amplification reactions. Findings: Clinical applicability of the system was demonstrated using the system to measure amplification with two different isothermal amplification technologies with significantly different temperature, volume, and fluorescence requirements: recombinase polymerase amplification (RPA) and reverse transcription loop-mediated isothermal amplification (RT-LAMP). RPA detection was demonstrated with a positive control DNA provided in a commercial kit while RT-LAMP detection of clinically meaningful levels of SARS-CoV-2 RNA was demonstrated in a custom RT-LAMP assay. In a preliminary analysis of nasopharyngeal swab samples from 74 individuals, the custom RT-LAMP assay showed a positive agreement of 92·3% and a negative agreement of 91·4% with the SARS-CoV-2 RT-qPCR test developed by the US Centers for Disease Control and Prevention. Interpretation: This open-source system was designed to improve accessibility to nucleic acid testing with isothermal amplification methods. The system can be easily produced using only a low-end 3D printer. Moreover, the use of single-board computers obviates the need to produce printed circuit boards. At a time when global supply chains are at their most fragile, open-source diagnostic equipment has the potential to reduce pandemic-related health inequities. Funding: International AIDS vaccine Initiative IAVI and USAID: award AID-OAA-A16-00032.
url http://www.sciencedirect.com/science/article/pii/S2214109X21001145
work_keys_str_mv AT jacksoncoolebs realtimeisothermalnucleicacidamplificationdetectioninresourcelimitedsettingsadescriptionofanopensourceminiaturefluorimeter
AT alexkortummsc realtimeisothermalnucleicacidamplificationdetectioninresourcelimitedsettingsadescriptionofanopensourceminiaturefluorimeter
AT yubotangphd realtimeisothermalnucleicacidamplificationdetectioninresourcelimitedsettingsadescriptionofanopensourceminiaturefluorimeter
AT imranvohrabs realtimeisothermalnucleicacidamplificationdetectioninresourcelimitedsettingsadescriptionofanopensourceminiaturefluorimeter
AT marynatoliphd realtimeisothermalnucleicacidamplificationdetectioninresourcelimitedsettingsadescriptionofanopensourceminiaturefluorimeter
AT kathrynkundrodphd realtimeisothermalnucleicacidamplificationdetectioninresourcelimitedsettingsadescriptionofanopensourceminiaturefluorimeter
AT rebeccarichardskortumphd realtimeisothermalnucleicacidamplificationdetectioninresourcelimitedsettingsadescriptionofanopensourceminiaturefluorimeter
_version_ 1724222156067307520