Global Inhomogeneity Index Evaluation of a DCT-based EIT Lung Imaging

Purpose: To evaluate a novel structural-functional DCT-based EIT lung imaging method against the classical EIT reconstruction. Method: Taken retrospectively from a former study, EIT data was evaluated using both reconstruction methods. For different phases of ventilation, EIT images are analyzed wit...

Full description

Bibliographic Details
Main Authors: Chen Rongqing, Möller Knut
Format: Article
Language:English
Published: De Gruyter 2020-09-01
Series:Current Directions in Biomedical Engineering
Subjects:
eit
dct
gi