Numerical Study of FRP Reinforced Concrete Slabs at Elevated Temperature
One-way glass fibre reinforced polymer (GFRP) reinforced concrete slabs at elevated temperatures are investigated through numerical modeling. Serviceability and strength requirements of ACI-440.1R are considered for the design of the slabs. Diagrams to determine fire endurance of slabs by employing...