In situ correction of field errors induced by temperature gradient in cryogenic undulators

A new technique of undulator field correction for cryogenic permanent magnet undulators (CPMUs) is proposed to correct the phase error induced by temperature gradient. This technique takes advantage of two important instruments: one is the in-vacuum self-aligned field analyzer with laser instrumenta...

Full description

Bibliographic Details
Main Authors: Takashi Tanaka, Takamitsu Seike, Akihiro Kagamihata, Thomas Schmidt, Alexander Anghel, Mark Brügger, Willy Bulgheroni, Bruno Jakob, Hideo Kitamura
Format: Article
Language:English
Published: American Physical Society 2009-12-01
Series:Physical Review Special Topics. Accelerators and Beams
Online Access:http://doi.org/10.1103/PhysRevSTAB.12.120702