Deuterium retention in MeV self-implanted tungsten: Influence of damaging dose rate

Recrystallized, polycrystalline tungsten was self-damaged by 20MeV tungsten ions up to a calculated damage dose in the damage peak of 0.23dpa. The time to acquire this dose and hence the average damaging dose rate was varied from 6×10-3 to 4×10-6dpa/s, the latter coming close to the damage dose rate...

Full description

Bibliographic Details
Main Author: T. Schwarz-Selinger
Format: Article
Language:English
Published: Elsevier 2017-08-01
Series:Nuclear Materials and Energy