Test circuit for verifying dielectric performance of phase-to-enclosure during capacitive current breaking

In the case of Extra High Voltage and Ultra High Voltage circuit breaker, almost all of testing laboratories adopt the single-phase testing method for verifying the performance of capacitive breaking capability, based on IEC 62271-100 Annex O, due to the limitation of testing facilities. For dead-ta...

Full description

Bibliographic Details
Main Authors: Jung-Hyeon Ryu, Jin-Hwan Kim, Seung-Jae Park, Kern-Joong Kim
Format: Article
Language:English
Published: Taylor & Francis Group 2016-01-01
Series:Journal of International Council on Electrical Engineering
Subjects:
Online Access:http://dx.doi.org/10.1080/22348972.2016.1158348
id doaj-96877f20b76a494b9e69d4329d9d8c57
record_format Article
spelling doaj-96877f20b76a494b9e69d4329d9d8c572020-11-24T23:14:25ZengTaylor & Francis GroupJournal of International Council on Electrical Engineering2234-89722016-01-016120220610.1080/22348972.2016.11583481158348Test circuit for verifying dielectric performance of phase-to-enclosure during capacitive current breakingJung-Hyeon Ryu0Jin-Hwan Kim1Seung-Jae Park2Kern-Joong Kim3Korea Electrotechnology Research InstituteKorea Electrotechnology Research InstituteKorea Electrotechnology Research InstituteChungNam National UniversityIn the case of Extra High Voltage and Ultra High Voltage circuit breaker, almost all of testing laboratories adopt the single-phase testing method for verifying the performance of capacitive breaking capability, based on IEC 62271-100 Annex O, due to the limitation of testing facilities. For dead-tank breaker, the tests for the insulating properties of phase-to-enclosure are recommended as a non-mandatory testing item. However, IEC MT36 has proposed the change of standard to specify as a mandatory in its next version planned in 2016. The peak of recovery voltages, occurring just after interrupting the some type of capacitive currents, arrives at different values on supply and load sides. With the technical background, the new capacitive current breaking test circuits are proposed to fulfill the next edition of IEC 62271-100 to be newly published. This paper illustrates the testing methods and simulation results for the single phase test circuits of capacitive current breaking, applicable to the circuit-breakers from 145 to 362 kV.http://dx.doi.org/10.1080/22348972.2016.1158348Capacitive current switching testsdead-tank breakerIEC 62271-100insulating propertyrecovery voltage
collection DOAJ
language English
format Article
sources DOAJ
author Jung-Hyeon Ryu
Jin-Hwan Kim
Seung-Jae Park
Kern-Joong Kim
spellingShingle Jung-Hyeon Ryu
Jin-Hwan Kim
Seung-Jae Park
Kern-Joong Kim
Test circuit for verifying dielectric performance of phase-to-enclosure during capacitive current breaking
Journal of International Council on Electrical Engineering
Capacitive current switching tests
dead-tank breaker
IEC 62271-100
insulating property
recovery voltage
author_facet Jung-Hyeon Ryu
Jin-Hwan Kim
Seung-Jae Park
Kern-Joong Kim
author_sort Jung-Hyeon Ryu
title Test circuit for verifying dielectric performance of phase-to-enclosure during capacitive current breaking
title_short Test circuit for verifying dielectric performance of phase-to-enclosure during capacitive current breaking
title_full Test circuit for verifying dielectric performance of phase-to-enclosure during capacitive current breaking
title_fullStr Test circuit for verifying dielectric performance of phase-to-enclosure during capacitive current breaking
title_full_unstemmed Test circuit for verifying dielectric performance of phase-to-enclosure during capacitive current breaking
title_sort test circuit for verifying dielectric performance of phase-to-enclosure during capacitive current breaking
publisher Taylor & Francis Group
series Journal of International Council on Electrical Engineering
issn 2234-8972
publishDate 2016-01-01
description In the case of Extra High Voltage and Ultra High Voltage circuit breaker, almost all of testing laboratories adopt the single-phase testing method for verifying the performance of capacitive breaking capability, based on IEC 62271-100 Annex O, due to the limitation of testing facilities. For dead-tank breaker, the tests for the insulating properties of phase-to-enclosure are recommended as a non-mandatory testing item. However, IEC MT36 has proposed the change of standard to specify as a mandatory in its next version planned in 2016. The peak of recovery voltages, occurring just after interrupting the some type of capacitive currents, arrives at different values on supply and load sides. With the technical background, the new capacitive current breaking test circuits are proposed to fulfill the next edition of IEC 62271-100 to be newly published. This paper illustrates the testing methods and simulation results for the single phase test circuits of capacitive current breaking, applicable to the circuit-breakers from 145 to 362 kV.
topic Capacitive current switching tests
dead-tank breaker
IEC 62271-100
insulating property
recovery voltage
url http://dx.doi.org/10.1080/22348972.2016.1158348
work_keys_str_mv AT junghyeonryu testcircuitforverifyingdielectricperformanceofphasetoenclosureduringcapacitivecurrentbreaking
AT jinhwankim testcircuitforverifyingdielectricperformanceofphasetoenclosureduringcapacitivecurrentbreaking
AT seungjaepark testcircuitforverifyingdielectricperformanceofphasetoenclosureduringcapacitivecurrentbreaking
AT kernjoongkim testcircuitforverifyingdielectricperformanceofphasetoenclosureduringcapacitivecurrentbreaking
_version_ 1725594470560301056