Extracting fluorescent reporter time courses of cell lineages from high-throughput microscopy at low temporal resolution.

The extraction of fluorescence time course data is a major bottleneck in high-throughput live-cell microscopy. Here we present an extendible framework based on the open-source image analysis software ImageJ, which aims in particular at analyzing the expression of fluorescent reporters through cell d...

Full description

Bibliographic Details
Main Authors: Mike J Downey, Danuta M Jeziorska, Sascha Ott, T Katherine Tamai, Georgy Koentges, Keith W Vance, Till Bretschneider
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2011-01-01
Series:PLoS ONE
Online Access:https://www.ncbi.nlm.nih.gov/pmc/articles/pmid/22194797/?tool=EBI
id doaj-986f69cff5644414add7b98f87a58b61
record_format Article
spelling doaj-986f69cff5644414add7b98f87a58b612021-03-03T20:30:55ZengPublic Library of Science (PLoS)PLoS ONE1932-62032011-01-01612e2788610.1371/journal.pone.0027886Extracting fluorescent reporter time courses of cell lineages from high-throughput microscopy at low temporal resolution.Mike J DowneyDanuta M JeziorskaSascha OttT Katherine TamaiGeorgy KoentgesKeith W VanceTill BretschneiderThe extraction of fluorescence time course data is a major bottleneck in high-throughput live-cell microscopy. Here we present an extendible framework based on the open-source image analysis software ImageJ, which aims in particular at analyzing the expression of fluorescent reporters through cell divisions. The ability to track individual cell lineages is essential for the analysis of gene regulatory factors involved in the control of cell fate and identity decisions. In our approach, cell nuclei are identified using Hoechst, and a characteristic drop in Hoechst fluorescence helps to detect dividing cells. We first compare the efficiency and accuracy of different segmentation methods and then present a statistical scoring algorithm for cell tracking, which draws on the combination of various features, such as nuclear intensity, area or shape, and importantly, dynamic changes thereof. Principal component analysis is used to determine the most significant features, and a global parameter search is performed to determine the weighting of individual features. Our algorithm has been optimized to cope with large cell movements, and we were able to semi-automatically extract cell trajectories across three cell generations. Based on the MTrackJ plugin for ImageJ, we have developed tools to efficiently validate tracks and manually correct them by connecting broken trajectories and reassigning falsely connected cell positions. A gold standard consisting of two time-series with 15,000 validated positions will be released as a valuable resource for benchmarking. We demonstrate how our method can be applied to analyze fluorescence distributions generated from mouse stem cells transfected with reporter constructs containing transcriptional control elements of the Msx1 gene, a regulator of pluripotency, in mother and daughter cells. Furthermore, we show by tracking zebrafish PAC2 cells expressing FUCCI cell cycle markers, our framework can be easily adapted to different cell types and fluorescent markers.https://www.ncbi.nlm.nih.gov/pmc/articles/pmid/22194797/?tool=EBI
collection DOAJ
language English
format Article
sources DOAJ
author Mike J Downey
Danuta M Jeziorska
Sascha Ott
T Katherine Tamai
Georgy Koentges
Keith W Vance
Till Bretschneider
spellingShingle Mike J Downey
Danuta M Jeziorska
Sascha Ott
T Katherine Tamai
Georgy Koentges
Keith W Vance
Till Bretschneider
Extracting fluorescent reporter time courses of cell lineages from high-throughput microscopy at low temporal resolution.
PLoS ONE
author_facet Mike J Downey
Danuta M Jeziorska
Sascha Ott
T Katherine Tamai
Georgy Koentges
Keith W Vance
Till Bretschneider
author_sort Mike J Downey
title Extracting fluorescent reporter time courses of cell lineages from high-throughput microscopy at low temporal resolution.
title_short Extracting fluorescent reporter time courses of cell lineages from high-throughput microscopy at low temporal resolution.
title_full Extracting fluorescent reporter time courses of cell lineages from high-throughput microscopy at low temporal resolution.
title_fullStr Extracting fluorescent reporter time courses of cell lineages from high-throughput microscopy at low temporal resolution.
title_full_unstemmed Extracting fluorescent reporter time courses of cell lineages from high-throughput microscopy at low temporal resolution.
title_sort extracting fluorescent reporter time courses of cell lineages from high-throughput microscopy at low temporal resolution.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2011-01-01
description The extraction of fluorescence time course data is a major bottleneck in high-throughput live-cell microscopy. Here we present an extendible framework based on the open-source image analysis software ImageJ, which aims in particular at analyzing the expression of fluorescent reporters through cell divisions. The ability to track individual cell lineages is essential for the analysis of gene regulatory factors involved in the control of cell fate and identity decisions. In our approach, cell nuclei are identified using Hoechst, and a characteristic drop in Hoechst fluorescence helps to detect dividing cells. We first compare the efficiency and accuracy of different segmentation methods and then present a statistical scoring algorithm for cell tracking, which draws on the combination of various features, such as nuclear intensity, area or shape, and importantly, dynamic changes thereof. Principal component analysis is used to determine the most significant features, and a global parameter search is performed to determine the weighting of individual features. Our algorithm has been optimized to cope with large cell movements, and we were able to semi-automatically extract cell trajectories across three cell generations. Based on the MTrackJ plugin for ImageJ, we have developed tools to efficiently validate tracks and manually correct them by connecting broken trajectories and reassigning falsely connected cell positions. A gold standard consisting of two time-series with 15,000 validated positions will be released as a valuable resource for benchmarking. We demonstrate how our method can be applied to analyze fluorescence distributions generated from mouse stem cells transfected with reporter constructs containing transcriptional control elements of the Msx1 gene, a regulator of pluripotency, in mother and daughter cells. Furthermore, we show by tracking zebrafish PAC2 cells expressing FUCCI cell cycle markers, our framework can be easily adapted to different cell types and fluorescent markers.
url https://www.ncbi.nlm.nih.gov/pmc/articles/pmid/22194797/?tool=EBI
work_keys_str_mv AT mikejdowney extractingfluorescentreportertimecoursesofcelllineagesfromhighthroughputmicroscopyatlowtemporalresolution
AT danutamjeziorska extractingfluorescentreportertimecoursesofcelllineagesfromhighthroughputmicroscopyatlowtemporalresolution
AT saschaott extractingfluorescentreportertimecoursesofcelllineagesfromhighthroughputmicroscopyatlowtemporalresolution
AT tkatherinetamai extractingfluorescentreportertimecoursesofcelllineagesfromhighthroughputmicroscopyatlowtemporalresolution
AT georgykoentges extractingfluorescentreportertimecoursesofcelllineagesfromhighthroughputmicroscopyatlowtemporalresolution
AT keithwvance extractingfluorescentreportertimecoursesofcelllineagesfromhighthroughputmicroscopyatlowtemporalresolution
AT tillbretschneider extractingfluorescentreportertimecoursesofcelllineagesfromhighthroughputmicroscopyatlowtemporalresolution
_version_ 1714822162361090048