Nonlinear Impedance of Whole Cells Near an Electrode as a Probe of Mitochondrial Activity

By simultaneously measuring the bulk media and electrode interface voltages of a yeast (Saccharomyces cerevisiae) suspension subjected to an AC voltage, a yeast-dependent nonlinear response was found only near the current injection electrodes. Computer simulation of yeast near a current injection el...

Full description

Bibliographic Details
Main Authors: John H. Miller Jr., Jie Fang, George T. Mercier, Akilan Palanisami
Format: Article
Language:English
Published: MDPI AG 2011-04-01
Series:Biosensors
Subjects:
Online Access:http://www.mdpi.com/2079-6374/1/2/46