Reliability analysis of application of variable frequency drive on condensate pump in nuclear power plant
The aim of this paper is to analyze the reliability of Variable Frequency Drives (VFD) when used to control condensate pump motor in a nuclear power plant. IEC 60812 system reliability analysis procedure for Failure Mode and Effects Analysis (FMEA) was used to determine the potential failure modes f...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Taylor & Francis Group
2019-01-01
|
Series: | Journal of International Council on Electrical Engineering |
Subjects: | |
Online Access: | http://dx.doi.org/10.1080/22348972.2018.1564548 |