Critical Hydraulic Eccentricity Estimation in Vertical Turbine Pump Impeller to Control Vibration

In many applications, pumps are tested against standard specifications to define the maximum allowable vibration amplitude limits of a pump. It is essential to identify the causes of vibration and methods to attenuate the same to ensure the safe and satisfactory operation of a pump. Causes of vibrat...

Full description

Bibliographic Details
Main Authors: Ravindra S. Birajdar, Appasaheb A. Keste, Shravan H. Gawande
Format: Article
Language:English
Published: Hindawi Limited 2021-01-01
Series:International Journal of Rotating Machinery
Online Access:http://dx.doi.org/10.1155/2021/6643282