A two-stage approach to induction and intubation of two infants with Pierre Robin Sequence using a LMA Classic™ and Air-Q®: two cases report

The laryngeal mask airway (LMA) Classic™ and Air-Q® are supralaryngeal devices used for airway management in routine and difficult pediatric airways. We describe a novel two-stage technique of insertion of the LMA Classic™ awake prior to induction of anesthesia, to assure oxygenation and ventilation...