Small punch tensile/fracture test data and 3D specimen surface data on Grade 91 ferritic/martensitic steel from cryogenic to room temperature

Raw data from small punch tensile/fracture tests at two displacement rates in the temperature range from −196 °C to room temperature on Grade 91 ferritic/martensitic steel are presented. A number of specimens were analyzed after testing by means of X-ray computed tomography (CT). Based on the CT vol...

Full description

Bibliographic Details
Main Authors: Matthias Bruchhausen, Jean-Marc Lapetite, Stefan Ripplinger, Tim Austin
Format: Article
Language:English
Published: Elsevier 2016-12-01
Series:Data in Brief