Compression test of cold-formedsteel perforated profile with steel sheathing

The subject of this paper is the stability and strength of cold-formed and perforated steel sigma-section columns with steel sheathing of different thickness. Ceilings with and without steel sheathing of different thickness are tested to failure in compression on a laboratory machine, which was base...

Full description

Bibliographic Details
Main Author: Shamanin Aleksandr Yur’evich
Format: Article
Language:English
Published: Moscow State University of Civil Engineering (MGSU) 2015-05-01
Series:Vestnik MGSU
Subjects:
Online Access:http://vestnikmgsu.ru/index.php/archive/article/download/2066