Upstream installation effects on metrological characteristics of flow sensors

The results of experimental investigation of upstream installation effects on metrological characteristics of the electromagnetic and turbine flow sensors of the nominal diameter DN50 are presented. The influence of inlet pipe diameter and influence of gasket diameter on accuracy of flow sensors we...

Full description

Bibliographic Details
Main Authors: Eugenijus Maslauskas, Gediminas Zygmantas
Format: Article
Language:English
Published: Vilnius Gediminas Technical University 2011-04-01
Series:Mokslas: Lietuvos Ateitis
Subjects:
Online Access:https://www.jbem.vgtu.lt/index.php/MLA/article/view/10776
id doaj-dd3071d3cab54aa994fed64e152feb66
record_format Article
spelling doaj-dd3071d3cab54aa994fed64e152feb662021-05-02T16:31:29ZengVilnius Gediminas Technical UniversityMokslas: Lietuvos Ateitis2029-23412029-22522011-04-011110.3846/mla.2009.1.13116Upstream installation effects on metrological characteristics of flow sensorsEugenijus Maslauskas0Gediminas Zygmantas1Lietuvos energetikos institutasLietuvos energetikos institutas The results of experimental investigation of upstream installation effects on metrological characteristics of the electromagnetic and turbine flow sensors of the nominal diameter DN50 are presented. The influence of inlet pipe diameter and influence of gasket diameter on accuracy of flow sensors were investigated. It was found that the most sensitive flow sensor on above mentioned flow disturbances are the turbine ones. The supplementary error caused by reduced inlet pipe diameter can increased up to 8 % meanwhile reduction of gasket inner diameter increases supplementary error up to 25 %. Investigated electromagnetic flow sensors are less sensitive to flow disturbances and supplementary error in the worse case was not more than ± 2,0 % Article in Lithuanian Įrengimo sąlygų įtaka srauto matuoklių metrologinėms charakteristikoms Anotacija. Darbe nagrinėjama įrengimo sąlygų įtaka elektromagnetinių ir turbininių srauto matuoklių metrologinėms charakteristikoms. Buvo tyrinėti vienodo vardinio skersmens (DN50) matuokliai esant 0,5–50 m3/h debitų diapazonui. Matavimai buvo atlikti, skaitiklius iš abiejų pusių prijungus vadinamaisiais standartiniais vamzdžiais (Dvid = 50,5 mm) – padidinto (55,2 mm) ir sumažinto (46,2 mm) skersmens. Be to, buvo tiriama tarpinių kiaurymės (∅50, ∅45 ir ∅40) įtaka. Matavimai parodė, kad turbininis srauto matuoklis jautriausiai reaguoja sumažinus tiek vamzdžio skersmenį, tiek ir tarpinę kiaurymę, o papildoma paklaida dėl skersmens sumažinimo gali padidėti net iki 25 %. Reikšminiai žodžiai: instaliavimo efektas, elektromagnetinis srauto matuoklis, turbininis srauto matuoklis, vamzdžio skersmuo, tarpinė, paklaida. https://www.jbem.vgtu.lt/index.php/MLA/article/view/10776installation effectelectromagnetic flow meterturbine flow meterpipe diameterspacer
collection DOAJ
language English
format Article
sources DOAJ
author Eugenijus Maslauskas
Gediminas Zygmantas
spellingShingle Eugenijus Maslauskas
Gediminas Zygmantas
Upstream installation effects on metrological characteristics of flow sensors
Mokslas: Lietuvos Ateitis
installation effect
electromagnetic flow meter
turbine flow meter
pipe diameter
spacer
author_facet Eugenijus Maslauskas
Gediminas Zygmantas
author_sort Eugenijus Maslauskas
title Upstream installation effects on metrological characteristics of flow sensors
title_short Upstream installation effects on metrological characteristics of flow sensors
title_full Upstream installation effects on metrological characteristics of flow sensors
title_fullStr Upstream installation effects on metrological characteristics of flow sensors
title_full_unstemmed Upstream installation effects on metrological characteristics of flow sensors
title_sort upstream installation effects on metrological characteristics of flow sensors
publisher Vilnius Gediminas Technical University
series Mokslas: Lietuvos Ateitis
issn 2029-2341
2029-2252
publishDate 2011-04-01
description The results of experimental investigation of upstream installation effects on metrological characteristics of the electromagnetic and turbine flow sensors of the nominal diameter DN50 are presented. The influence of inlet pipe diameter and influence of gasket diameter on accuracy of flow sensors were investigated. It was found that the most sensitive flow sensor on above mentioned flow disturbances are the turbine ones. The supplementary error caused by reduced inlet pipe diameter can increased up to 8 % meanwhile reduction of gasket inner diameter increases supplementary error up to 25 %. Investigated electromagnetic flow sensors are less sensitive to flow disturbances and supplementary error in the worse case was not more than ± 2,0 % Article in Lithuanian Įrengimo sąlygų įtaka srauto matuoklių metrologinėms charakteristikoms Anotacija. Darbe nagrinėjama įrengimo sąlygų įtaka elektromagnetinių ir turbininių srauto matuoklių metrologinėms charakteristikoms. Buvo tyrinėti vienodo vardinio skersmens (DN50) matuokliai esant 0,5–50 m3/h debitų diapazonui. Matavimai buvo atlikti, skaitiklius iš abiejų pusių prijungus vadinamaisiais standartiniais vamzdžiais (Dvid = 50,5 mm) – padidinto (55,2 mm) ir sumažinto (46,2 mm) skersmens. Be to, buvo tiriama tarpinių kiaurymės (∅50, ∅45 ir ∅40) įtaka. Matavimai parodė, kad turbininis srauto matuoklis jautriausiai reaguoja sumažinus tiek vamzdžio skersmenį, tiek ir tarpinę kiaurymę, o papildoma paklaida dėl skersmens sumažinimo gali padidėti net iki 25 %. Reikšminiai žodžiai: instaliavimo efektas, elektromagnetinis srauto matuoklis, turbininis srauto matuoklis, vamzdžio skersmuo, tarpinė, paklaida.
topic installation effect
electromagnetic flow meter
turbine flow meter
pipe diameter
spacer
url https://www.jbem.vgtu.lt/index.php/MLA/article/view/10776
work_keys_str_mv AT eugenijusmaslauskas upstreaminstallationeffectsonmetrologicalcharacteristicsofflowsensors
AT gediminaszygmantas upstreaminstallationeffectsonmetrologicalcharacteristicsofflowsensors
_version_ 1721490001442635776