AC flashover dynamic theoretical and experimental model under fan‐shaped and longitudinal pollution on silicone rubber insulator

Abstract Due to wind and uneven distribution of the field along the insulator, a kind of non‐uniform contamination is deposited on the insulator surface as fan‐shaped and longitudinal pollution. This paper investigates such non‐uniform pollution from theoretical and experimental points of view. For...