Corrosion Resistance of a Plasma-Oxidized Ti6Al4V Alloy for Dental Applications

A Ti6Al4V alloy was plasma-oxidized at 600 °C during 1, 2, 3, 5 and 8 h and corroded in an artificial saliva solution. Electrochemical evaluation was performed by using potentiodynamic polarization curves, linear polarization resistance (LPR), and electrochemical impedance spectroscopy (EIS) measure...

Full description

Bibliographic Details
Main Authors: N. Velazquez-Torres, J. Porcayo-Calderon, H. Martinez-Valencia, R. Lopes-Cecenes, I. Rosales-Cadena, E. Sarmiento-Bustos, C. I. Rocabruno-Valdés, J. G. Gonzalez-Rodriguez
Format: Article
Language:English
Published: MDPI AG 2021-09-01
Series:Coatings