Use of performance-monitoring to improve reliability of emergency diesel generators

Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Nuclear Engineering, 1998. === Includes bibliographical references (p. 149-151). === Emergency diesel generators are one of the most important contributors to the core damage failure rate of nuclear power plants. Current required testing...

Full description

Bibliographic Details
Main Author: Dulik, Jeffrey D. (Jeffrey Daniel)
Other Authors: Michael W. Golay.
Format: Others
Language:English
Published: Massachusetts Institute of Technology 2009
Subjects:
Online Access:http://hdl.handle.net/1721.1/47682