Design, fabrication and mechanical optimization of a flexural high speed nanopositioning imaging stage

Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2009. === Includes bibliographical references (p. 204-206). === The intent of this research is to generate the knowledge required to design, fabricate and operate a device capable of high speed nano-scale vertical...

Full description

Bibliographic Details
Main Author: Panas, Robert M. (Robert Matthew)
Other Authors: Martin L. Culpepper.
Format: Others
Language:English
Published: Massachusetts Institute of Technology 2010
Subjects:
Online Access:http://hdl.handle.net/1721.1/50558
id ndltd-MIT-oai-dspace.mit.edu-1721.1-50558
record_format oai_dc
spelling ndltd-MIT-oai-dspace.mit.edu-1721.1-505582019-05-02T16:35:01Z Design, fabrication and mechanical optimization of a flexural high speed nanopositioning imaging stage Panas, Robert M. (Robert Matthew) Martin L. Culpepper. Massachusetts Institute of Technology. Dept. of Mechanical Engineering. Massachusetts Institute of Technology. Dept. of Mechanical Engineering. Mechanical Engineering. Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2009. Includes bibliographical references (p. 204-206). The intent of this research is to generate the knowledge required to design, fabricate and operate a device capable of high speed nano-scale vertical positioning of microscopy samples. The high speed focusing device (HSFD) created during this research utilizes a new combination of technologies for the purpose of imaging: Lorentz coil actuation, flexural bearings and strain gage sensing. The application of the technologies combined with precision design principles, as used in the HSFD, result in a demonstrated combination of performance and cost gains over a measured commercially available system. The HSFD is able to perform steps with 8 ms 95% settling time, 2% dynamic accuracy, and 0.005% static accuracy while operating with a resolution of 10.5 nm (l[sigma]) over a range of 500 [mu]m at a cost of about $1400. This performance is 3x faster stepping, 2x better dynamic accuracy, ~~100x better static accuracy, equivalent resolution and range to the top of the line commercial devices at less than half of the cost. The reduced cost is envisioned to enable greater distribution and use of nano-positioning imaging stages, while the increased performance is envisioned to enable faster, more benign (in the case of biological sciences) and more precise imaging. The increased use and data gathering ability of the new device are envisioned to enable fields of research such as biology and materials science to extend their bounds further into the micro/nano-scale as well as further along the time scale for both high speed and low speed processes. by Robert M. Panas. S.M. 2010-01-07T20:52:57Z 2010-01-07T20:52:57Z 2009 2009 Thesis http://hdl.handle.net/1721.1/50558 463628833 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 217 p. application/pdf Massachusetts Institute of Technology
collection NDLTD
language English
format Others
sources NDLTD
topic Mechanical Engineering.
spellingShingle Mechanical Engineering.
Panas, Robert M. (Robert Matthew)
Design, fabrication and mechanical optimization of a flexural high speed nanopositioning imaging stage
description Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2009. === Includes bibliographical references (p. 204-206). === The intent of this research is to generate the knowledge required to design, fabricate and operate a device capable of high speed nano-scale vertical positioning of microscopy samples. The high speed focusing device (HSFD) created during this research utilizes a new combination of technologies for the purpose of imaging: Lorentz coil actuation, flexural bearings and strain gage sensing. The application of the technologies combined with precision design principles, as used in the HSFD, result in a demonstrated combination of performance and cost gains over a measured commercially available system. The HSFD is able to perform steps with 8 ms 95% settling time, 2% dynamic accuracy, and 0.005% static accuracy while operating with a resolution of 10.5 nm (l[sigma]) over a range of 500 [mu]m at a cost of about $1400. This performance is 3x faster stepping, 2x better dynamic accuracy, ~~100x better static accuracy, equivalent resolution and range to the top of the line commercial devices at less than half of the cost. The reduced cost is envisioned to enable greater distribution and use of nano-positioning imaging stages, while the increased performance is envisioned to enable faster, more benign (in the case of biological sciences) and more precise imaging. The increased use and data gathering ability of the new device are envisioned to enable fields of research such as biology and materials science to extend their bounds further into the micro/nano-scale as well as further along the time scale for both high speed and low speed processes. === by Robert M. Panas. === S.M.
author2 Martin L. Culpepper.
author_facet Martin L. Culpepper.
Panas, Robert M. (Robert Matthew)
author Panas, Robert M. (Robert Matthew)
author_sort Panas, Robert M. (Robert Matthew)
title Design, fabrication and mechanical optimization of a flexural high speed nanopositioning imaging stage
title_short Design, fabrication and mechanical optimization of a flexural high speed nanopositioning imaging stage
title_full Design, fabrication and mechanical optimization of a flexural high speed nanopositioning imaging stage
title_fullStr Design, fabrication and mechanical optimization of a flexural high speed nanopositioning imaging stage
title_full_unstemmed Design, fabrication and mechanical optimization of a flexural high speed nanopositioning imaging stage
title_sort design, fabrication and mechanical optimization of a flexural high speed nanopositioning imaging stage
publisher Massachusetts Institute of Technology
publishDate 2010
url http://hdl.handle.net/1721.1/50558
work_keys_str_mv AT panasrobertmrobertmatthew designfabricationandmechanicaloptimizationofaflexuralhighspeednanopositioningimagingstage
_version_ 1719043516173123584