A Study for the Particle Characteristics and the Validation of Breather Port Performance of 300mm Wafer FOUP/LPU Systems

碩士 === 國立臺北科技大學 === 冷凍與低溫科技研究所 === 91 === A minienvironment system combined with FOUP (Front Opening Unified Pod) and LPU(Load Port Unit) is the main wafer transmission equipment in 300mm wafer manufacturing processes. FOUP is used to held and transport of wafers, while LPU is used to ope...

Full description

Bibliographic Details
Main Authors: CHUN-MING CHEN, 陳俊銘
Other Authors: SHIH-CHENG HU
Format: Others
Language:zh-TW
Published: 2003
Online Access:http://ndltd.ncl.edu.tw/handle/58639444769837590559
id ndltd-TW-091TIT00703009
record_format oai_dc
spelling ndltd-TW-091TIT007030092015-10-13T13:35:32Z http://ndltd.ncl.edu.tw/handle/58639444769837590559 A Study for the Particle Characteristics and the Validation of Breather Port Performance of 300mm Wafer FOUP/LPU Systems 300mm晶圓載卸模組FOUP/LPU之汙染粒子特性及裝設呼吸孔有效性確認之研究 CHUN-MING CHEN 陳俊銘 碩士 國立臺北科技大學 冷凍與低溫科技研究所 91 A minienvironment system combined with FOUP (Front Opening Unified Pod) and LPU(Load Port Unit) is the main wafer transmission equipment in 300mm wafer manufacturing processes. FOUP is used to held and transport of wafers, while LPU is used to open the side door of FOUP and makes the wafer stored in FOUP can be loaded into the production machine through a robot arm. During the operating procedures, some problems need to be placed importance on. For example, whether the particles produced by colliding with FOUP and the joint surface of minienvironment will enter the system? Whether the negative pressure produced by instant action of opening side door of FOUP will make the particles outside of system contaminate the wafers? If FOUP equipped with a breather port, can FOUP exclude the particles outside of system? These all are the key technical bottlenecks. Using a manometer, an oxygen detector and several particle counters, this thesis establishes a complete testing process to practically estimate the particle problems under various conditions. In addition, using oxygen detector and air compressor, the leakage characteristics of the FOUPs were quantitatively determined. SHIH-CHENG HU 胡石政 2003 學位論文 ; thesis 88 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺北科技大學 === 冷凍與低溫科技研究所 === 91 === A minienvironment system combined with FOUP (Front Opening Unified Pod) and LPU(Load Port Unit) is the main wafer transmission equipment in 300mm wafer manufacturing processes. FOUP is used to held and transport of wafers, while LPU is used to open the side door of FOUP and makes the wafer stored in FOUP can be loaded into the production machine through a robot arm. During the operating procedures, some problems need to be placed importance on. For example, whether the particles produced by colliding with FOUP and the joint surface of minienvironment will enter the system? Whether the negative pressure produced by instant action of opening side door of FOUP will make the particles outside of system contaminate the wafers? If FOUP equipped with a breather port, can FOUP exclude the particles outside of system? These all are the key technical bottlenecks. Using a manometer, an oxygen detector and several particle counters, this thesis establishes a complete testing process to practically estimate the particle problems under various conditions. In addition, using oxygen detector and air compressor, the leakage characteristics of the FOUPs were quantitatively determined.
author2 SHIH-CHENG HU
author_facet SHIH-CHENG HU
CHUN-MING CHEN
陳俊銘
author CHUN-MING CHEN
陳俊銘
spellingShingle CHUN-MING CHEN
陳俊銘
A Study for the Particle Characteristics and the Validation of Breather Port Performance of 300mm Wafer FOUP/LPU Systems
author_sort CHUN-MING CHEN
title A Study for the Particle Characteristics and the Validation of Breather Port Performance of 300mm Wafer FOUP/LPU Systems
title_short A Study for the Particle Characteristics and the Validation of Breather Port Performance of 300mm Wafer FOUP/LPU Systems
title_full A Study for the Particle Characteristics and the Validation of Breather Port Performance of 300mm Wafer FOUP/LPU Systems
title_fullStr A Study for the Particle Characteristics and the Validation of Breather Port Performance of 300mm Wafer FOUP/LPU Systems
title_full_unstemmed A Study for the Particle Characteristics and the Validation of Breather Port Performance of 300mm Wafer FOUP/LPU Systems
title_sort study for the particle characteristics and the validation of breather port performance of 300mm wafer foup/lpu systems
publishDate 2003
url http://ndltd.ncl.edu.tw/handle/58639444769837590559
work_keys_str_mv AT chunmingchen astudyfortheparticlecharacteristicsandthevalidationofbreatherportperformanceof300mmwaferfouplpusystems
AT chénjùnmíng astudyfortheparticlecharacteristicsandthevalidationofbreatherportperformanceof300mmwaferfouplpusystems
AT chunmingchen 300mmjīngyuánzàixièmózǔfouplpuzhīwūrǎnlìzitèxìngjízhuāngshèhūxīkǒngyǒuxiàoxìngquèrènzhīyánjiū
AT chénjùnmíng 300mmjīngyuánzàixièmózǔfouplpuzhīwūrǎnlìzitèxìngjízhuāngshèhūxīkǒngyǒuxiàoxìngquèrènzhīyánjiū
AT chunmingchen studyfortheparticlecharacteristicsandthevalidationofbreatherportperformanceof300mmwaferfouplpusystems
AT chénjùnmíng studyfortheparticlecharacteristicsandthevalidationofbreatherportperformanceof300mmwaferfouplpusystems
_version_ 1717738374550257664