Measurements of Liquid Slip in Hydrophobic Microchannels

碩士 === 逢甲大學 === 航太與系統工程所 === 99 === The objective of this study is to experimentally determine the slip length in the hydrophobic microchannel with pressure-driven liquid flow. Two test model of PDMS material are fabricated using MEMS technique. Both the models are of the same length 5cm and width 1...

Full description

Bibliographic Details
Main Authors: HSIU-HAO WU, 吳修豪
Other Authors: Chyi-Yeou Soong
Format: Others
Language:zh-TW
Published: 2011
Online Access:http://ndltd.ncl.edu.tw/handle/13735650094141084408