Base test method for gravity loaded standing seam roof systems

The base test method provides a means of determining the load-carrying capacity of multiple spans, multiple purlin line standing seam roof systems. The method uses results from a single span, simply supported, two purlin line experimental tests, the 1986 American Iron and Steel Institute Specificati...