Low pressure and salt effect on the ethanol-water vapour-liquid equilibrium

Vapour-liquid equilibrium data for the ethanol-water system were obtained at 70, 80, 90, 100, 150, 300 and 500 mm Hg absolute pressure. No azeotrope was detected at 70 and 80 mm Hg. Azeotropic data were estimated at other experimental pressures. The VLE data were obtained using a modified Othmer sti...

Full description

Bibliographic Details
Main Author: Njenga, H. N.
Published: Swansea University 1991
Subjects:
541