The influence of prior creep damage on the fracture localisation in X20 CrMoV12-1 cross-weld creep tests

Many of Eskom's coal fired power plants have an average age of 170 000 hours and a few operating close to 300 000 hours. Main steam temperatures experienced in a power plant vary between 535-555°C. These operating conditions place main steam pipe components to operate within the creep regime. I...

Full description

Bibliographic Details
Main Author: Rasiawan, Trisha
Other Authors: Sonderegger, Bernhard
Format: Dissertation
Language:English
Published: University of Cape Town 2018