Accurate ionic bond energy measurements with TCID mass spectrometry and imaging PEPICO spectroscopy

Two projects are presented here. In the first, metal-cyclopentadienyl bond dissociation energies (BDEs) were measured for seven metallocene ions (Cp2M+, Cp = η5-cyclopentadienyl = c-C5H5, M = Ti, V, Cr, Mn, Fe, Co, Ni) using threshold collision-induced dissociation (TCID) performed in a guided ion b...

Full description

Bibliographic Details
Main Author: Rowland, Tyson G.
Format: Others
Published: Scholarly Commons 2012
Subjects:
Online Access:https://scholarlycommons.pacific.edu/uop_etds/809
https://scholarlycommons.pacific.edu/cgi/viewcontent.cgi?article=1808&context=uop_etds
id ndltd-pacific.edu-oai-scholarlycommons.pacific.edu-uop_etds-1808
record_format oai_dc
spelling ndltd-pacific.edu-oai-scholarlycommons.pacific.edu-uop_etds-18082021-10-05T05:13:08Z Accurate ionic bond energy measurements with TCID mass spectrometry and imaging PEPICO spectroscopy Rowland, Tyson G. Two projects are presented here. In the first, metal-cyclopentadienyl bond dissociation energies (BDEs) were measured for seven metallocene ions (Cp2M+, Cp = η5-cyclopentadienyl = c-C5H5, M = Ti, V, Cr, Mn, Fe, Co, Ni) using threshold collision-induced dissociation (TCID) performed in a guided ion beam tandem mass spectrometer. For all seven room temperature metallocene ions, the dominant dissociation pathway was simple Cp loss from the metal. Traces of other fragment ions were also detected, such as C10H10+, C10H8+, C8H8+, C3H3+, H2M+, C3H3M+, C6H6M+, and C7H6M+, depending on the metal center. Statistical modeling of the Cp-loss TCID experimental data, including consideration of energy distributions, multiple collisions, and kinetic shifts, allow the extraction of 0 K [CpM+ - Cp] BDEs. These are found to be 4.95 ± 0.15, 4.02 ± 0.14, 4.22 ± 0.13, 3.51 ± 0.12, 4.26 ± 0.15, 4.57 ± 0.15, and 3.37 ± 0.12 eV for Cp2To+, Cp2V+, Cp2Cr+, Cp2Mn+, Cp2Fe+, Cp2Co+, and Cp2Ni+, respectively. The measured BDE trend is largely in line with arguments based on a simple molecular orbital picture, with the exceptions of a reversal in Cp2Mn+ and Cp2Ni+ BDEs (although within uncertainty), and the exceptional case of titanocene, most likely attributable to its bent structure. The new results presented here are compared to previous literature values and are found to provide a more complete and accurate set of thermochemical parameters. In the second project, imaging photoelectron photoion coincidence (iPEPICO) spectroscopy has been used to determine 0 K appearance energies for the unimolecular dissociation reactions of several energy selected 1-alkyl iodide cations n-CnH2n+1I+ → CnH2n+1+ + I, (n = 2-5). The 0 K appearance energies of the iodine-loss fragment ions were determined to be 9.836 ± 0.010, 9.752 ± 0.010, 9.721 ± 0.010, and 9.684 ± 0.010 eV for n-C3H7I, n-C4H9I, n-C5H11I, and n-C6H13I molecules, respectively. Isomerization of then-alkyl iodide structures into 2-iodo species adds complexity to this study. Using literature adiabatic ionization energies, ionic bond dissociation energies were calculated for the four modeled iodoalkyl cations and it was shown that as the alkyl chain length increases, the carbon-halogen bond strength decreases, supporting the suggestions set forth by inductive effects. In the modeling with statistical energy distributions and rate theory, the role of hindered rotors was also evaluated and no strong experimental evidence was found either way. The heaviest species in the series, heptyl iodide (C7H15I) was also measured via iPEPICO and showed to have a greater complexity of fragmentation than the lighter analogs. Sequential dissociation of the first fragment ion, C7H15+ leads to C4H9+, C5H11+, and C3H7+ ions in competitive dissociation processes, dominated at low energies by the C4H9+ cation. 2012-01-01T08:00:00Z text application/pdf https://scholarlycommons.pacific.edu/uop_etds/809 https://scholarlycommons.pacific.edu/cgi/viewcontent.cgi?article=1808&context=uop_etds University of the Pacific Theses and Dissertations Scholarly Commons University of the Pacific Thesis;Photoelectron spectroscopy;Metallocenes;Mass spectrometry Chemistry Physical Sciences and Mathematics
collection NDLTD
format Others
sources NDLTD
topic University of the Pacific Thesis;Photoelectron spectroscopy;Metallocenes;Mass spectrometry
Chemistry
Physical Sciences and Mathematics
spellingShingle University of the Pacific Thesis;Photoelectron spectroscopy;Metallocenes;Mass spectrometry
Chemistry
Physical Sciences and Mathematics
Rowland, Tyson G.
Accurate ionic bond energy measurements with TCID mass spectrometry and imaging PEPICO spectroscopy
description Two projects are presented here. In the first, metal-cyclopentadienyl bond dissociation energies (BDEs) were measured for seven metallocene ions (Cp2M+, Cp = η5-cyclopentadienyl = c-C5H5, M = Ti, V, Cr, Mn, Fe, Co, Ni) using threshold collision-induced dissociation (TCID) performed in a guided ion beam tandem mass spectrometer. For all seven room temperature metallocene ions, the dominant dissociation pathway was simple Cp loss from the metal. Traces of other fragment ions were also detected, such as C10H10+, C10H8+, C8H8+, C3H3+, H2M+, C3H3M+, C6H6M+, and C7H6M+, depending on the metal center. Statistical modeling of the Cp-loss TCID experimental data, including consideration of energy distributions, multiple collisions, and kinetic shifts, allow the extraction of 0 K [CpM+ - Cp] BDEs. These are found to be 4.95 ± 0.15, 4.02 ± 0.14, 4.22 ± 0.13, 3.51 ± 0.12, 4.26 ± 0.15, 4.57 ± 0.15, and 3.37 ± 0.12 eV for Cp2To+, Cp2V+, Cp2Cr+, Cp2Mn+, Cp2Fe+, Cp2Co+, and Cp2Ni+, respectively. The measured BDE trend is largely in line with arguments based on a simple molecular orbital picture, with the exceptions of a reversal in Cp2Mn+ and Cp2Ni+ BDEs (although within uncertainty), and the exceptional case of titanocene, most likely attributable to its bent structure. The new results presented here are compared to previous literature values and are found to provide a more complete and accurate set of thermochemical parameters. In the second project, imaging photoelectron photoion coincidence (iPEPICO) spectroscopy has been used to determine 0 K appearance energies for the unimolecular dissociation reactions of several energy selected 1-alkyl iodide cations n-CnH2n+1I+ → CnH2n+1+ + I, (n = 2-5). The 0 K appearance energies of the iodine-loss fragment ions were determined to be 9.836 ± 0.010, 9.752 ± 0.010, 9.721 ± 0.010, and 9.684 ± 0.010 eV for n-C3H7I, n-C4H9I, n-C5H11I, and n-C6H13I molecules, respectively. Isomerization of then-alkyl iodide structures into 2-iodo species adds complexity to this study. Using literature adiabatic ionization energies, ionic bond dissociation energies were calculated for the four modeled iodoalkyl cations and it was shown that as the alkyl chain length increases, the carbon-halogen bond strength decreases, supporting the suggestions set forth by inductive effects. In the modeling with statistical energy distributions and rate theory, the role of hindered rotors was also evaluated and no strong experimental evidence was found either way. The heaviest species in the series, heptyl iodide (C7H15I) was also measured via iPEPICO and showed to have a greater complexity of fragmentation than the lighter analogs. Sequential dissociation of the first fragment ion, C7H15+ leads to C4H9+, C5H11+, and C3H7+ ions in competitive dissociation processes, dominated at low energies by the C4H9+ cation.
author Rowland, Tyson G.
author_facet Rowland, Tyson G.
author_sort Rowland, Tyson G.
title Accurate ionic bond energy measurements with TCID mass spectrometry and imaging PEPICO spectroscopy
title_short Accurate ionic bond energy measurements with TCID mass spectrometry and imaging PEPICO spectroscopy
title_full Accurate ionic bond energy measurements with TCID mass spectrometry and imaging PEPICO spectroscopy
title_fullStr Accurate ionic bond energy measurements with TCID mass spectrometry and imaging PEPICO spectroscopy
title_full_unstemmed Accurate ionic bond energy measurements with TCID mass spectrometry and imaging PEPICO spectroscopy
title_sort accurate ionic bond energy measurements with tcid mass spectrometry and imaging pepico spectroscopy
publisher Scholarly Commons
publishDate 2012
url https://scholarlycommons.pacific.edu/uop_etds/809
https://scholarlycommons.pacific.edu/cgi/viewcontent.cgi?article=1808&context=uop_etds
work_keys_str_mv AT rowlandtysong accurateionicbondenergymeasurementswithtcidmassspectrometryandimagingpepicospectroscopy
_version_ 1719487480735989760