Secondary ion emission from single massive gold cluster impacts

Secondary ion mass spectrometry, SIMS, is one of the most versatile surface analytical techniques. The significant parameter determining the performance of SIMS is the secondary ion yield. Atomic projectiles, traditionally used in SIMS, are an inefficient method to desorb and generate secondary ions...

Full description

Bibliographic Details
Main Author: Hager, George Joseph
Other Authors: Schweikert, Emile A.
Format: Others
Language:en_US
Published: Texas A&M University 2007
Subjects:
Online Access:http://hdl.handle.net/1969.1/5899
id ndltd-tamu.edu-oai-repository.tamu.edu-1969.1-5899
record_format oai_dc
spelling ndltd-tamu.edu-oai-repository.tamu.edu-1969.1-58992013-01-08T10:38:52ZSecondary ion emission from single massive gold cluster impactsHager, George JosephSIMSmassive clustersSecondary ion mass spectrometry, SIMS, is one of the most versatile surface analytical techniques. The significant parameter determining the performance of SIMS is the secondary ion yield. Atomic projectiles, traditionally used in SIMS, are an inefficient method to desorb and generate secondary ions. The use of poly-atomic projectiles, such as (CsI)nCs, Au3, SF5 and C60, has been demonstrated to be an effective means to enhance secondary ion yields. Still larger secondary ion yields can be obtained with massive gold clusters, specifically Au4004+. Secondary ion yields from organic targets approach unity and are in excess of unity for selected inorganic targets. This dissertation is a first study of the secondary ion emission characteristics resulting from surface bombardment of keV Au400. The enhanced secondary ion yields from these massive clusters resulted in a need to detect isobaric secondary ions. An eight-anode detector was designed, built and implemented to study secondary ion emission resulting from massive projectile impacts. Secondary ion yield enhancements, resulting from use of the multi-anode detector, are reported along with secondary ion distributions for organic and inorganic targets. Au-adduct ions have been observed in mass spectra resulting form organic and inorganic targets bombarded by Au400. Data indicate that these adducts are a result of projectile/surface molecule interactions and not a product of Au implantation. Secondary ion yields of these adducts are reported. Although these adduct ion yields are an order of magnitude lower than the non-adduct ions, we have demonstrated their potential usefulness in analytical applications, such as examining surface homogeneity. Finally, these novel projectiles have been used to examine secondary ion emission from targets with different structural properties which have the same stoichiometry. In a comparative study, we have measured a significant difference in secondary ion emission and yields from the two systems, graphite and α-ZrP. Au400, at 136 keV, is effective in terms of secondary ion yield and secondary ion multiplicity enhancement. When used in the event-by-event bombardment/detection mode, the desorption volume has a diameter between 10-20 nm with and emission depth of approximately 5 nm, perturbing less than an attomole of analyte.Texas A&M UniversitySchweikert, Emile A.2007-09-17T19:37:18Z2007-09-17T19:37:18Z2003-052007-09-17T19:37:18ZBookThesisElectronic Dissertationtext1876472 byteselectronicapplication/pdfborn digitalhttp://hdl.handle.net/1969.1/5899en_US
collection NDLTD
language en_US
format Others
sources NDLTD
topic SIMS
massive clusters
spellingShingle SIMS
massive clusters
Hager, George Joseph
Secondary ion emission from single massive gold cluster impacts
description Secondary ion mass spectrometry, SIMS, is one of the most versatile surface analytical techniques. The significant parameter determining the performance of SIMS is the secondary ion yield. Atomic projectiles, traditionally used in SIMS, are an inefficient method to desorb and generate secondary ions. The use of poly-atomic projectiles, such as (CsI)nCs, Au3, SF5 and C60, has been demonstrated to be an effective means to enhance secondary ion yields. Still larger secondary ion yields can be obtained with massive gold clusters, specifically Au4004+. Secondary ion yields from organic targets approach unity and are in excess of unity for selected inorganic targets. This dissertation is a first study of the secondary ion emission characteristics resulting from surface bombardment of keV Au400. The enhanced secondary ion yields from these massive clusters resulted in a need to detect isobaric secondary ions. An eight-anode detector was designed, built and implemented to study secondary ion emission resulting from massive projectile impacts. Secondary ion yield enhancements, resulting from use of the multi-anode detector, are reported along with secondary ion distributions for organic and inorganic targets. Au-adduct ions have been observed in mass spectra resulting form organic and inorganic targets bombarded by Au400. Data indicate that these adducts are a result of projectile/surface molecule interactions and not a product of Au implantation. Secondary ion yields of these adducts are reported. Although these adduct ion yields are an order of magnitude lower than the non-adduct ions, we have demonstrated their potential usefulness in analytical applications, such as examining surface homogeneity. Finally, these novel projectiles have been used to examine secondary ion emission from targets with different structural properties which have the same stoichiometry. In a comparative study, we have measured a significant difference in secondary ion emission and yields from the two systems, graphite and α-ZrP. Au400, at 136 keV, is effective in terms of secondary ion yield and secondary ion multiplicity enhancement. When used in the event-by-event bombardment/detection mode, the desorption volume has a diameter between 10-20 nm with and emission depth of approximately 5 nm, perturbing less than an attomole of analyte.
author2 Schweikert, Emile A.
author_facet Schweikert, Emile A.
Hager, George Joseph
author Hager, George Joseph
author_sort Hager, George Joseph
title Secondary ion emission from single massive gold cluster impacts
title_short Secondary ion emission from single massive gold cluster impacts
title_full Secondary ion emission from single massive gold cluster impacts
title_fullStr Secondary ion emission from single massive gold cluster impacts
title_full_unstemmed Secondary ion emission from single massive gold cluster impacts
title_sort secondary ion emission from single massive gold cluster impacts
publisher Texas A&M University
publishDate 2007
url http://hdl.handle.net/1969.1/5899
work_keys_str_mv AT hagergeorgejoseph secondaryionemissionfromsinglemassivegoldclusterimpacts
_version_ 1716503680428015616